-40%

Altronix AL1024ULACM Access Power Controller, Power Supply/Charger 8 Fused Relay

$ 163.67

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Country/Region of Manufacture: United States
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Custom Bundle: No
  • Model: AL1024ULACM
  • Brand: Altronix
  • Condition: New
  • MPN: AL1024ULACM
  • Modified Item: No
  • UPC: 782239935765
  • Return shipping will be paid by: Buyer

    Description

    Designer Entryway
    Welcome to Designer Entryway.
    HAVE A QUESTION? -
    Click to find out more
    Feedback
    Add to Favorites
    Join Mailing List
    CATEGORIES
    Home
    Home & Garden
    Consumer Electronics
    Business & Industrial
    Computers/Tablets & Networking
    More
    Musical Instruments & Gear
    eBay Motors
    Cell Phones & Accessories
    Cameras & Photo
    Sporting Goods
    Everything Else
    Quick Delivery On All Items
    100% Satisfaction Guaranteed
    Money Back Guarantee
    Product information
    Altronix AL1024ULACM Access Power Controller, Power Supply/Charger 8 Fused Relay
    Click on the Image to Enlarge
    Description
    AL1024ULACM
    Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 24VDC @ 10A, FAI, 115VAC, BC400 Enclosure
    Altronix AL1024ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 10A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
    Input
    Input 115VAC 60Hz rated @ 4.2A.
    Power supply input options:
    a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
    b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
    Eight (8) Access Control System trigger inputs.
    Input options:
    a) Eight (8) normally open (NO) inputs.
    b) Eight (8) open collector inputs.
    c) Any combination of the above.
    Output
    24VDC @ 10A supply current.
    Eight (8) independently controlled outputs.
    Output options:
    a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
    Eight (8) auxiliary power outputs (unswitched)
    Output ratings:
    Fuses are rated @ 3.5A.
    Filtered and electronically regulated outputs (built-in power supply).
    ACM8 board main fuse is rated at 10A.
    Supervision
    AC fail supervision (form "C" contacts).
    Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
    Low battery and battery presence supervision (form "C" contact).
    Features
    Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    a) Normally open (NO) or normally closed (NC) dry contact input.
    b) Polarity reversal input from FACP signaling circuit.
    Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
    Short circuit and thermal overload protection.
    Visual Indicators
    Red LEDs indicate outputs are triggered (relays energized).
    Green LED indicates FACP disconnect is triggered.
    AC input and DC output LED indicators.
    Battery Backup
    Built-in charger for sealed lead acid or gel type batteries.
    Automatic switch over to stand-by battery when AC fails.
    Zero voltage drop when unit switches over to battery backup (AC failure condition).
    AC fail supervision (form "C" contact).
    Battery fail and battery presence supervision (form "C" contact).
    Temperature
    Operating: 0ºC to 49ºC (32ºF to 120ºF).
    Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).
    Relative Humidity 85% +/- 5%.
    BTU/Hr. (approx.): 123 BTU/Hr
    Payment
    We accept Paypal as payment method.
    Returns
    Returns Accepted, Buyer, 30 Days, eBay Return Policy for Exchange or Money Back. All Products has to be in Original Packaging, not used, all seals intact and in a perfect condition.
    Designer Entryway, LLC. only accept products returns from the returning party within 30 days of date of original purchase by the customer.
    All Return Items Must Be returned to the address provided with the RMA document following the description of the specific defect ( i. e, reason for the return). However, failure to submit any item could impact the eligibility for credit. Upon receipt Designer Entryway, LLC. will assess the condition of the product and will determine if a defect exist in the material/product and will be result for final judgment to determine the final credit.
    All Electronic items are to be inspected, in working conditions also they are subject to be inspected for matching Serial numbers from our records.
    Contact us
    To contact our Customer Service Team, simply click
    Send Message
    and our Customer Service team will be happy to assist.
    We accept Paypal as payment method.
    Returns Accepted, Buyer, 30 Days, eBay Return Policy for Exchange or Money Back. All Products has to be in Original Packaging, not used, all seals intact and in a perfect condition.
    Designer Entryway, LLC. only accept products returns from the returning party within 30 days of date of original purchase by the customer.
    All Return Items Must Be returned to the address provided with the RMA document following the description of the specific defect ( i. e, reason for the return). However, failure to submit any item could impact the eligibility for credit. Upon receipt Designer Entryway, LLC. will assess the condition of the product and will determine if a defect exist in the material/product and will be result for final judgment to determine the final credit.
    All Electronic items are to be inspected, in working conditions also they are subject to be inspected for matching Serial numbers from our records.
    To contact our Customer Service Team, simply click
    Send Message
    and our Customer Service team will be happy to assist.
    Join Our Exclusive Newsletter For Up To Date News, Special Offers And New Arrivals
    Sign up Now
    Quick Links
    Feedback
    Add to Favorites
    Contact us
    Get in touch with us
    Designer Entryway LLC
    Kissimmee, Florida
    Postal Code 34745
    United States
    Payment info
    Copyright 2019
    Designer Entryway LLC.
    All Rights Reserved
    Listing and template services provided by inkFrog